• +2-35734687

  • sales@technoscientific.net

Stay Connected:

Series FED 115 | Drying and heating chambers Avantgarde.Line with forced convection and enhanced timer functions

code : FED115

mportant characteristics

  • Temperature range: ambient temperature plus 10 °C to 300 °C
  • Up to 30% lower energy consumption compared to conventional units on the market
  • High temperature accuracy thanks to APT.line™ technology
  • Adjustable fan speed
  • Controller with LCD display and enhanced time functions
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Stackable
  • Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • Ethernet interface
  • USB port for recording data

Select version
Rated voltage Option model Version Art. No. MSRP*[?] Selection Bookmark
Model FED 115
230 V 1~ 50/60 Hz

Standard

FED115-230V¹ 9010-0293 - +
120 V 1~ 60 Hz

Standard

FED115UL-120V¹ 9010-0294 - +
* Recommended retail price
Designation FED115UL-120V¹ FED115-230V¹
Option model Standard Standard
Order number 9010-0294 9010-0293
Measures
Interior volume [cu.ft.] 4.1 4.1
Net weight of the unit (empty) [lbs] 119 119
permitted load [lbs] 331 331
Load per rack [lbs] 66 66
Doors
Unit doors 1 1
Internal Dimensions
Width [in] 21.67 21.67
Height [in] 21.67 21.67
Depth [in] 15.17 15.17
Outer dimensions
Width net [in] 27.97 27.97
Height net [in] 28.96 28.96
Depth net [in] 23.84 23.84
Wall clearance back [in] 6.3 6.3
Wall clearance sidewise [in] 3.94 3.94
Environment-specific data
Energy consumption at 150 °C [Wh/h] 340 340
Sound-pressure level [dB(A)] 43 43
Fixtures
Number of shelves (std./max.) 2/5 2/5
Performance Data Temperature
Temperature range 10 °C above ambient temperature to [°C] 300 300
Temperature variation at 150 °C [± K] 1.2 1.2
Temperature fluctuation at 150 °C [± K] 0.3 0.3
Heating-up time to 150 °C [min] 18 18
Recovery time after 30 seconds door open at 150 °C [min] 4 4
Electrical data
Rated Voltage [V] 120 230
Power frequency [Hz] 60 50/60
Nominal power [kW] 0 1.3
Unit fuse [A] 12.5 6.3
Phase (Nominal voltage) 1~ 1~
  1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.

Accessories Series FED 115 | Drying and heating chambers Avantgarde.Line with forced convection and enhanced timer functions