• +2-35734687

  • sales@technoscientific.net

Stay Connected:

Series FD 260 | Drying and heating chambers Avantgarde.Line with forced convection

code : FD260

Important characteristics

  • Temperature range: ambient temperature plus 10 °C to 300 °C
  • Up to 30% lower energy consumption compared to conventional units on the market
  • High temperature accuracy thanks to APT.line™ technology
  • Forced convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • USB port for recording data

Select version
Rated voltage Option model Version Art. No. MSRP*[?] Selection Bookmark
Model FD 260
240 V 1~ 60 Hz

Standard

FD260UL-240V¹ 9010-0310 - +
230 V 1~ 50/60 Hz

Standard

FD260-230V¹ 9010-0309 - +
* Recommended retail price
Designation FD260UL-240V¹ FD260-230V¹
Option model Standard Standard
Order number 9010-0310 9010-0309
Measures
Interior volume [L] 259 259
Net weight of the unit (empty) [kg] 85 85
permitted load [kg] 270 270
Load per rack [kg] 40 40
Doors
Unit doors 1 1
Internal Dimensions
Width [mm] 650 650
Height [mm] 780 780
Depth [mm] 515 515
Outer dimensions
Width net [mm] 810 810
Height net [mm] 965 965
Depth net [mm] 760 760
Wall clearance back [mm] 160 160
Wall clearance sidewise [mm] 100 100
Environment-specific data
Energy consumption at 150 °C [Wh/h] 410 410
Sound-pressure level [dB(A)] 43 43
Fixtures
Number of shelves (std./max.) 2/8 2/8
Data
  - -
Online
Shop URL https://www.binder-shop.com/us/oven/oven-with-forced-convection-fd260ul-240v -
Performance Data Temperature
Temperature range 10 °C above ambient temperature to [°C] 300 300
Temperature variation at 150 °C [± K] 1.9 1.9
Temperature fluctuation at 150 °C [± K] 0.4 0.4
Heating-up time to 150 °C [min] 19 19
Recovery time after 30 seconds door open at 150 °C [min] 5 5
Electrical data
Rated Voltage [V] 240 230
Power frequency [Hz] 60 50/60
Nominal power [kW] 2.5 2.3
Unit fuse [A] 16 12.5
Phase (Nominal voltage) 1~ 1~
  1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.

Accessories Series FD 260 | Drying and heating chambers Avantgarde.Line with forced convection