Series FED 720 | Drying and heating chambers Avantgarde.Line with forced convection and enhanced timer functions

code : FED720

Important characteristics

  • Temperature range: ambient temperature plus 12 °C to 300 °C
  • Up to 30% lower energy consumption compared to conventional units on the market
  • High temperature accuracy thanks to APT.line™ technology
  • Adjustable fan speed
  • Controller with LCD display and enhanced time functions
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • Ethernet interface
  • USB port for recording data

Select version
Rated voltage Option model Version Art. No. MSRP*[?] Selection Bookmark
Model FED 720
400 V 3~ 50/60 Hz

Standard

FED720-400V¹ 9010-0301 - +
208 V 3~ 60 Hz

Standard

FED720UL-208V¹ 9010-0302 - +
* Recommended retail price
Designation FED720UL-208V¹ FED720-400V¹
Option model Standard Standard
Order number 9010-0302 9010-0301
Measures
Interior volume [cu.ft.] 26.2 26.2
Net weight of the unit (empty) [lbs] 366 366
permitted load [lbs] 694 694
Load per rack [lbs] 99 99
Doors
Unit doors 2 2
Internal Dimensions
Width [in] 39.4 39.4
Height [in] 51.2 51.2
Depth [in] 22.46 22.46
Outer dimensions
Width net 1165 mm 1165 mm
Width net [in] 45.9 45.9
Height net [in] 62.6 62.6
Height net 1590 mm 1590 mm
Depth net [in] 34.28 34.28
Depth net 870 mm 870 mm
Wall clearance back 160 mm 160 mm
Wall clearance back [in] 6.3 6.3
Wall clearance sidewise [in] 3.94 3.94
Environment-specific data
Energy consumption at 150 °C [Wh/h] 800 800
Sound-pressure level [dB(A)] 43 43
Fixtures
Number of shelves (std./max.) 2/16 2/16
Performance Data Temperature
Temperature range 12 °C above ambient temperature to [°C] 300 300
Temperature variation at 150 °C [± K] 2 2
Temperature range 12 °C above ambient temperature to 300 °C 300 °C
Temperature fluctuation at 150 °C [± K] 0.6 0.6
Heating-up time to 150 °C [min] 25 25
Temperature variation at 150 °C 2,0 ± K 2,0 ± K
Temperature fluctuation at 150 °C 6105.00 ASE-EUR 0,6 ± K 0,6 ± K
Heating-up time to 150 °C 25 min 25 min
Recovery time after 30 seconds door open at 150 °C [min] 6 6
Air change data
Air change (approx.) at 100 °C [x/h] 5 5
Electrical data
Rated Voltage [V] 208 400
Power frequency [Hz] 60 50/60
Nominal power [kW] 4.5 4.5
Unit fuse [A] 3 x 16 3 x 16
Phase (Nominal voltage) 3~ 3~
  1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.

Accessories Series FED 720 | Drying and heating chambers Avantgarde.Line with forced convection and enhanced timer functions