• +2-35734687

  • sales@technoscientific.net

Stay Connected:

AURA Mini Benchtop laminar flow cabinet

code : AURA Mini

AURA MiniTM Cabinets are supplied in one compact size only (895mm ). 
These state of the art compact down-flow cabinets, provide an ultimate cleanliness Class 100 work area where the highest safety for the products is achieved. 
The internal design, the air flow aerodynamics, the special H14 filter and the Filtrete® exhaust filter (or prefilters) guarantees the highest performances at the most stringent safety levels and operator comfort. 
Two operating modes are available: inward air barrier and outward air barrier.

 

  • INWARD air barrier. In this configuration an air barrier flows through the front opening and is recirculated with the downflow air by a motor blower. 70% of the air is returned to the work area through the main HEPA filter and 30% is exhausted into the environment through a Filtrete® exhaust filter with gravimetric efficiency of 99% on 3µm particles. In this configuration an excellent product protection is ensured, as well as an outstanding containment.
  • OUTWARD air barrier. In this case the air is sucked through the Filtrete® prefilter, mixed with the incoming recirculating air and then filtered through the main HEPA filter into the work area: here 30% of the air is exhausted through the front opening and 70% is recirculated. This configuration ensures the highest product protection.


In the INWARD configuration this unit can easily be used as an “active PCR” cabinet for DNA carry over blocking.
AURA MiniTM is a complete and user friendly tool for the protection of highly sensitive products that only experienced European design with over 35 years of know how and accurate quality manufacturing, can provide.

Main specifications

1. Centrifugal Motorblower.

2. Soft-touch keys on the control panel provide control of fan and lighting

3. Elapsed time-meter AURA MiniTM Series Downflow CABINETS: When space is at a premium EuroClone S.p.A. Via Figino 20/22, 20016 Pero (MI) - Italy Phone: +39.02.38195.1 - Fax +39.02.38101465 e-mail: info@euroclone.it www.euroclone.it EuroClone S.p.A. has a Quality System certified in compliance with UNI EN ISO 9001:2008 and NF EN ISO 13485:2004

4. Exhaust filter

5. Removable perforated work surface and back wall of the work chamber made of AISI 304 stainless steel

6. Cabinet outer surfaces made of cold rolled steel with paint finish

7. Front and side panels in tempered glass

8. H14 class High Efficiency Particulate Air filters guaranteed with 99.999% efficiency on 0.3 Micron particles (most penetrating particle diameter) (EN1822-1 and EN 13091:1999 tested and certified)

9. Exhaust filter (or pre-filter) type Filtrete® with a gravimetric efficiency higher than 99% on 3µm particles

10. Standard features includes: Fluorescent lamp, elapsed Time meter, UV and fluorescent lamps interconnected

11. Electrical equipment according to International Standards and EMC directives

12. Soft touch keys on the control panel provide control of the lighting, motor blower, UV light

13. Lighting › 800 lux

14. Silent and quite operation <60dB(A) due to the highly vibration-free suspensions of the fan.

Technical Specifications

• Compact, vertical laminar air flow cabinet.

Reduced size for the easiest installation in small or crowded labs.

• Easily convertible inward or outward barrier operating modes.

• Hinged front panel and side panels in tempered glass

• H14 downflow filter

• Filtrete® exhaust filter (or prefilters depending on configurations)

• Active PCR version

• Silent and quite operation <60dB(A)

AURA MiniTM Cabinets are supplied in one compact size only (895mm ). These state of the art compact down-flow cabinets, provide an ultimate cleanliness Class 100 work area where the highest safety for the products is achieved. The internal design, the air flow aerodynamics, the special H14 filter and the Filtrete® exhaust filter (or prefilters) guarantees the highest performances at the most stringent safety levels and operator comfort. Two operating modes are available: inward air barrier and outward air barrier. INWARD air barrier. In this configuration an air barrier flows through the front opening and is recirculated with the downflow air by a motor blower. 70% of the air is returned to the work area through the main HEPA filter and 30% is exhausted into the environment through a Filtrete® exhaust filter with gravimetric efficiency of 99% on 3µm particles. In this configuration an excellent product protection is ensured, as well as an outstanding containment. OUTWARD air barrier. In this case the air is sucked through the Filtrete® prefilter, mixed with the incoming recirculating air and then filtered through the main HEPA filter into the work area: here 30% of the air is exhausted through the front opening and 70% is recirculated. This configuration ensures the highest product protection. In the INWARD configuration this unit can easily be used as an “active PCR” cabinet for DNA carry over blocking. AURA MiniTM is a complete and user friendly tool for the protection of highly sensitive products that only experienced European design with over 35 years of know how and accurate quality manufacturing, can provide

Accessories AURA Mini Benchtop laminar flow cabinet