AZURA UHPLC System

code : A46010

 

System Proposal

This system features a AZURA P 6.1L LPG pump, an Autosampler 6.1L, a column thermostat CT 2.1, a DAD 6.1L UV/VIS detector with 8-variable UV measuring channels from 190 - 1000 nm, as well as a Tablet PC with AZURA Mobile Control.It is the UHPLC system with a backpressure range of 1000 bar. It perfectly fits the demanding needs of a method development system, as well as the robust fitness of a routine analysis machine.

The P6.1L with a HPG configuration features a solvent selection valve to set up to 4 solvents to the system of which two can be blended simultaneously. The internal degassing unit will prevent air bubbles in the system. Every P 6.1L comes with an attached mixing chamber, which can be changed to a larger volume depending on the applications needs.

The DAD 2.1L features a novel light path and flow cell architecture with improved handling and excellent performance. The frontal lamp and cell change ensures easy and secure maintenance. The temperature controlled optical bench minimizes signal drift. The wide flow cell selection allows the DAD 2.1L to be easily adapted to your needs.

The Autosampler 6.1L can inject 0.1 – 5000 µl to have a large flexibility. Using standard vials or two microtiter plates will give you a maximum sample capacity of up to 768 samples or 108 vials.

The AZURA CT 2.1 is the new price attractive basic column thermostat. It is suitable for column thermostatization above and below room temperature. The instrument operates with a microprocessor controlled Peltier element for exact temperature settings.

Key features

  • Complete gradient analytical HPLC system
  • Variable multichannel UV/VIS Detector (or DAD)
  • Pump unit with pressure sensor for a low pulsation eluent supply (max. 1000 bar)
  • AZURA Mobile Control unit allows direct control of all integrated modules
  • Complete software package ClarityChrom
  • Mobile Control for maintenance and diagnostics
  • Leakage protection
  • PC with Monitor

 

 

 

 

Let your application define your system solution.

In HPLC, components of a mixture are carried through the stationary phase by the flow of a mobile phase and separation is based on differences in migration rates among the sample components. Therefore, the nature of your analytes defines not only the method but also the HPLC system.

Main characteristics of the analytes:

MOLECULAR WEIGHT defines the pore size of the stationary phase

SOLUBILITY defines the HPLC mode, chemistry of stationary phase and eluent.

CONCENTRATION AND MATRIX defines the detection parameters and column dimensions.

The solubility of your analytes defines the HPLC mode. The elutropic series defines the solvent strength for the most often used chromatography modes normal phase and reversed phase.

 

AZURA® Analytical HPLC/UHPLC

Efficient and adaptable to your needs

The analytical HPLC and UHPLC systems of the KNAUER AZURA liquid chromatography instruments are designed to support and facilitate your work. Whether doing routine analysis or demanding separation tasks, AZURA systems are the right tool to overcome your analytical challenges. Choose between different gradient forming technologies and maximum flow rates to find the best configuration for your task.

 

 

Analytical system

Application area UHPLC
Pump system Gradient
Gradient Binary HPG
Injection Autosampler
Detector Diode array detection DAD
Software Mobile Control, ClarityChrom
Pressure 1000 bar
Column thermostat Yes

Accessories AZURA UHPLC System