• +2-35734687

  • sales@technoscientific.net

Stay Connected:

BD 56

code : BD 56

Important characteristics

  • Temperature range: ambient temperature plus 5 °C to 100 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Gravity convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • Inner door made of tempered safety glass
  • 2 chrome-plated racks
  • Units up to 115 L are stackable
  • Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • USB port for recording data

Select version
Rated voltage Option model Version Art. No. MSRP*[?] Selection Bookmark
Model BD 56
230 V 1~ 50/60 Hz

Standard

BD056-230V¹ 9010-0323 - +
120 V 1~ 50/60 Hz

Standard

BD056UL-120V¹ 9010-0324 - +
* Recommended retail price
Designation BD056UL-120V¹ BD056-230V¹
Option model Standard Standard
Order number 9010-0324 9010-0323
Measures
Interior volume [L] 57 57
Net weight of the unit (empty) [kg] 39 39
permitted load [kg] 70 70
Load per rack [kg] 30 30
Doors
Unit doors 1 1
Internal Dimensions
Width [mm] 360 360
Height [mm] 420 420
Depth [mm] 380 380
Outer dimensions
Width net [mm] 560 560
Height net [mm] 625 625
Depth net [mm] 565 565
Wall clearance sidewise [mm] 100 100
Wall clearance back [mm] 160 160
Environment-specific data
Energy consumption at 37 °C [Wh/h] 25 25
Fixtures
Number of shelves (std./max.) 2/4 2/4
Data
  - -
Online
Shop URL https://www.binder-shop.com/us/incubators/standard-incubators/standard-incubator-with-gravity-convection-bd260ul-120v -
Performance Data Temperature
Temperature range 5 °C above ambient temperature to [°C] 100 100
Temperature variation at 37 °C [± K] 0.3 0.3
Temperature fluctuation at 37 °C [± K] 0,1 ± K 0,1 ± K
Heating-up time to 37 °C [min] 42 42
Recovery time after 30 seconds door open at 37 °C [min] 15 15
Electrical data
Rated Voltage [V] 120 230
Power frequency [Hz] 50/60 50/60
Nominal power [kW] 0.3 0.3
Unit fuse [A] 12.5 6.3
Phase (Nominal voltage) 1~ 1~
  1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any tim

Accessories BD 56