• +2-35734687

  • sales@technoscientific.net

Stay Connected:

BF260

code : BF260

Important characteristics

  • Temperature range: ambient temperature plus 7 °C to 100 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Forced convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • Inner door made of tempered safety glass
  • 2 chrome-plated racks
  • Class 3.1 integrated independent temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • USB port for recording data

Select version
Rated voltage Option model Version Art. No. MSRP*[?] Selection Bookmark
Model BF 260
230 V 1~ 50/60 Hz

Standard

BF260-230V¹ 9010-0319 - +
120 V 1~ 60 Hz

Standard

BF260UL-120V¹ 9010-0320 - +
* Recommended retail price

 

Designation BF260UL-120V¹ BF260-230V¹
Option model Standard Standard
Order number 9010-0320 9010-0319
Measures
Interior volume [L] 257 257
Net weight of the unit (empty) [kg] 85 85
permitted load [kg] 270 270
Load per rack [kg] 40 40
Doors
Unit doors 1 1
Internal Dimensions
Width [mm] 650 650
Height [mm] 780 780
Depth [mm] 510 510
Outer dimensions
Width net [mm] 810 810
Height net [mm] 965 965
Depth net [mm] 760 760
Wall clearance back [mm] 160 160
Wall clearance sidewise [mm] 100 100
Environment-specific data
Energy consumption at 37 °C [Wh/h] 65 65
Sound-pressure level [dB(A)] 43 43
Fixtures
Number of shelves (std./max.) 2/8 2/8
Data
  - -
Performance Data Temperature
Temperature range 7 °C above ambient temperature to [°C] 100 100
Temperature variation at 37 °C [± K] 0.3 0.2
Temperature fluctuation at 37 °C [± K] 0,1 ± K 0,1 ± K
Heating-up time to 37 °C [min] 7 7
Recovery time after 30 seconds door open at 37 °C [min] 3 3
Electrical data
Rated Voltage [V] 120 230
Power frequency [Hz] 60 50/60
Nominal power [kW] 1 0.9
Unit fuse [A] 12.5 8
Phase (Nominal voltage) 1~ 1~
  1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.

Accessories BF260