• +2-35734687

  • sales@technoscientific.net

Stay Connected:

Series KB | Refrigerated incubators with compressor technology

code : KB23

Important characteristics

  • Temperature range: 0 °C to 100 °C
  • APT.line™ preheating chamber technology
  • Cooling with compressor cooling unit
  • Adjustable fan speed
  • Controller with time-segment and real-time programming
  • Elapsed time indicator
  • Inner door made of tempered safety glass
  • 2 stainless steel racks
  • Stackable
  • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm

Rated voltage Option model Version Art. No. MSRP*[?] Selection Bookmark
Model KB 23
230 V 1~ 50/60 Hz

Standard

KB023-230V¹ 9020-0112 - +
120 V 1~ 60 Hz

Standard

KB023UL-120V¹ 9020-0113 - +
* Recommended retail price

 

Designation KB023UL-120V¹ KB023-230V¹
Option model Standard Standard
Order number 9020-0113 9020-0112
Measures
Interior volume [L] 20 20
Net weight of the unit (empty) [kg] 44 44
permitted load [kg] 25 25
Load per rack [kg] 10 10
Doors
Inner doors 1 1
Unit doors 1 1
Internal Dimensions
Width [mm] 222 222
Height [mm] 330 330
Depth [mm] 277 277
Outer dimensions
Width net [mm] 435 435
Height net [mm] 620 620
Depth net [mm] 520 520
Wall clearance back [mm] 100 100
Wall clearance sidewise [mm] 100 100
Environment-specific data
Energy consumption at 40 °C [Wh/h] 60 60
Sound-pressure level [dB(A)] 47 47
Fixtures
Number of shelves (std./max.) 2/3 2/3
Online
Shop URL https://www.binder-shop.com/us/incubators/refrigerated-incubators/refrigerated-incubator-with-compressor-technology-kb023ul-120v -
Performance Data Temperature
Temperature range [°C] 0…100 0…100
Temperature variation at 37 °C [± K] 0.3 0.3
Temperature fluctuation at 37 °C [± K] 0,1 ± K 0,1 ± K
Heating-up time to 37 °C [min] 11 11
Recovery time after 30 seconds door open at 37 °C [min] 2 2
Electrical data
Rated Voltage [V] 120 230
Power frequency [Hz] 60 50/60
Nominal power [kW] 0.3 0
Unit fuse [A] 12.5 10
Phase (Nominal voltage) 1~ 1~
  1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.