• +2-35734687

  • sales@technoscientific.net

Stay Connected:

NanoPhotometer NP80

code : NP80

Introducing NP Mobile

The smarter spectrophotometer allowing more focused research & applications now accessible via your tablet & smartphone devices to take your research anywhere.

Dimensions

 implen, nanophotometer, spectrophotometer, nanodrop alternative, nano drop,
 

Weight

3.8-5.2 kg depending on configuration

 

Processing Power/Software

implen, nanophotometer, spectrophotometer, nanodrop alternative, nano drop, np80_angle

  • Linux based NPOS
  • Quad Core 1 GHz Processor
  • 32 GB Internal Storage
  • 2x USB A, USB B, HDMI, Ethernet, WLAN
 

Speed

1 GHz

 

Display

1024 x 600 pixels; Touch-Screen glove compatible

implen, nanophotometer, spectrophotometer, nanodrop alternative, nano drop, 12.16_N60_HIRES_camerascreen14_top2

 

Built-in 
Battery Pack

Optional rechargeable lithium ion battery; 95Wh, 6.6Ah; Operation time: up to 10 h; min. charging cycles: 800

 

NanoVolume Performance

 

Detection Range dsDNA 1 ng/µl to 16,500 ng/µl
Detection Range BSA 0.03 mg/ml to 478 mg/ml
Minimum Sample Size 0.3 µl
Photometric Range (10 mm equivalent) 0.02 – 330 A
Path Length 0.67 and 0.07 mm
Dilution Factor 15 and 140
Vortexer 2,800 rpm; tube size up to 2.0 ml

 

 

Cuvette Performance

 

Detection Range dsDNA 0.1 ng/µl to 130 ng/µl
Detection Range BSA 0.003 mg/ml to 3.7 mg/ml
Photometric Range 0 – 2.6 A
Center Height (Z-Height) 8.5 mm
Cell Types outside dimension 12.5 x 12.5 mm
Heating 37°C ± 0.5°C

 

 

Optical Specifications

 

Wavelength Scan Range 200 – 900 nm
Measure Time For Full Scan Range 3.5 seconds
Wavelength Reproducibility ± 0.2 nm
Wavelength Accuracy ± 0.75 nm
Bandwidth 1.8 nm
Stray Light < 0.5% at 220 nm using NaI
Absorbance Reproducibility < 0.002 A (0.67 mm path) @ 280 nm
Absorbance Accuracy ±0.002 A or ±1% of the reading, whichever is greater
Zero Stability ±0.003 A/hour after 20 min warm up @ 280 nm
Noise 0.002 A rms at 0 A @ 280 nm
0.002 A (pk to pk) at 0 A @ 280 nm
Optical Arrangement 1 x 3648 CCD Array
Lamp Xenon flash lamp
Lifetime 109 flashes, up to 10 years

 

 

Compatibility Requirements

Control Options Onboard with built-in touch screen, computer, smartphone and tablet
Software Compatibility Windows 7, 8, 10 (32 & 64 bit), OS X, iOS and Android OS
Min. Requirement Smart Phone/Tablet 4 inch screen
Apple: iPad 2, iPhone5 and iOS 6
Android Phone: OS Version 4.4
Android Tablet: OS version 5.0, Quadcore 1.2 GHz with 1 GB RAM

Accessories NanoPhotometer NP80